Vortex Suppression Baskets & Spool Combination
South Mesquite WTP, Texas
CASE STUDY #5
Problem:
Extreme Turbulence at the bottom of the wet well affecting the 4 pumps performance and longevity.
Solution:
Vortex Suppression Baskets & Spool combination welded together utilizing three points of flow straightening:
- 1st stage: 1″ wide square grate mounted near the bottom
- 2nd stage uses thirty (30) side wall vanes mounted 12 degree apart
- 3rd stage straightening grid mounted in the pipe, size 3.5″ x 3.5″ square.
SCOPE OF SUPPLY (Four Flow Straighteners)
Two (2) 13″ Diameter x 25.75″ Height
Two (2) 11.65″ Diameter x 25.75″ Height
MATERIALS OF CONSTRUCTION:
316L Stainless Steel
316L Stainless Steel
CUSTOMER:
North Texas Municipal Water District
South Mesquite WTP UV/Filter Imp
CONTRACTOR:
Archer Western Construction
Irving, TX 75038
ENGINEER:
Black & Veatch
Kansas City, MO 64114